Brand:BAI CHUANG
The Electromagnetic cold or heat flowmeter is compact, has a short connection size, and its lining and electrode materials are suitable for a wide range of liquids and slurries. Due to the square wave pulse excitation, the whole machine has low...
External environment requirements: The flowmeter should avoid installation in places where the temperature changes greatly or is exposed to high temperature radiation of the equipment, and if it must be installed, there must be heat insulation and...
Electromagnetic cold or heat flowmeter working principle: When water flows through the integrated heat meter or combined heat meter installed in the heat exchange system, according to the flow rate given by the flow sensor and the water supply and...
The measuring principle of electromagnetic flowmeter is based on Faraday's law of electromagnetic induction. The measuring tube of the flowmeter is a short non-permeable alloy tube lined with insulating material. Two electrodes are fixed on the...
Heat calculation method and normal working conditions Heat calculation method: This electromagnetic heating and cooling meter follows the urban construction industry standard CJ128-2007 of the People's Republic of China. Heat measurement: When water...